Medical

U.S. Vascular at St. Luke’s Cornwall Hospital

Cornwall, NY

  • Renovations to 5,600 square foot existing space for a new Angio Suite
  • New heating, ventilation and air conditioning systems
  • New sanitary plumbing systems
  • Alterations to existing fire protection sprinkler systems
  • New lighting and control systems
  • Additions to existing fire alarm systems
  • Additions and alterations to existing electrical power systems

Garnet Health Medical Center, Middletown, NY

Cooling System

    • Feasibility study for addition of a redundant cooling system to serve operating rooms, recovery, central sterile supply, cath lab and invasive radiation at facility
    • Review and evaluate existing mechanical, electrical and structural systems
    • Identify options and evaluate impacts and provide order of magnitude cost estimate to establish project budget
    • Design new 475 ton air cooled packaged chiller system, including AHU coils, pumps, piping and controls to provide redundant cooling to 12 operating rooms

Central Sterile Boiler Room Air Conditioning

    • Perform load calculations to determine equipment size
    • Design a water cooled air conditioning system to serve area

Humidifier Steam Main

    • New steam main and condensate return pumps to serve 3 humidifiers
    • New branch circuitry to power condensate return pumps and heat tracing

Standby Generator

      • Design of standby generator system to provide back-up power for all operating rooms
      • New automatic transfer switch, new switchboards and wiring

Crystal Run Healthcare X-Ray Room

    • Survey existing mechanical and electrical systems
    • Perform HVAC load calculations and design HVAC, fire protection and electrical system modifications and additions for new X-Ray room and installation of equipment

Crystal Run Healthcare, Middletown, NY

Completion of various projects at medical facilities and offices of healthcare system.

 

Crystal Run Healthcare X-Ray Room

    • Survey existing mechanical and electrical systems
    • Perform HVAC load calculations and design HVAC, fire protection and electrical system modifications and additions for new X-Ray room and installation of equipment

Crystal Run Healthcare Oncology Dispensing

    • Perform HVAC load calculations and design system modifications and additions for new dispensing and office rooms
    • Electrical system modifications and additions for lighting and power
    • Fire protection sprinkler system modifications and additions
    • Sanitary plumbing and water supply for new sink in dispensing room

The Heart Center, Poughkeepsie, NY

    • Mechanical and electrical system renovation designed to fit-up a 3,300 square foot medical office building in an existing building
    • Ducted HVAC systems
    • Completed sanitary plumbing, power, lighting and fire protection systems

Kingston Hospital, Kingston, NY

    • Design of mechanical and electrical alterations to a 5,200 square foot medical office in an existing building
    • Ducted HVAC systems
    • Completed sanitary plumbing, power, lighting and fire alarm systems

Women’s Health Center, Monroe, NY

    • Design of electrical systems for a new 33,000 square foot medical facility
    • Electrical service and distribution
    • Standby power generation
    • Completed general power, lighting and fire alarm systems